AS 1670.3:2024 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 3: Fire alarm monitoring
Standards Australia
This Standard was prepared by the Standards Australia Committee FP-002, Fire Detection, Warning, Control and Intercom Systems, to supersede AS 1670.3:2018, Fire detection, warning, control and intercom systems — System design, installation and commissioning, Part 3: Fire alarm monitoring.
This Standard will be referenced in the National Construction Code (NCC).
The objective of this Standard is to achieve the reliable monitoring of fire detection and alarm systems (FDAS) installed in buildings by a remotely located monitoring service and to transfer required signals to a fire dispatch centre.
Changes to this edition include the following:
(a) Introduces the Standardised Data Interface for the transmission of real time fire event data to the responding fire appliances.
(b) Introduces the concept of designated detection zone group. This enables specific areas within the FDAS to be independently monitored.
(c) Introduces the concept of multiple FDAS integrated within the building or site. This enables specific areas within the building or structures forming the building to be provided with an independent FDAS and for each FDAS to be independently monitored.
(d) Provides new definitions for clarity.
(e) Provides details of permitted transmission path formats.
The terms “normative” and “informative” have been used in this Standard to define the application of the appendices to which they apply. A “normative” appendix is an integral part of a Standard, whereas an “informative” appendix is only for information and guidance.
AS 1670.3:2024 achieves the reliable monitoring of fire detection and alarm systems (FDAS) installed in buildings by a remotely located monitoring service and to transfer required signals to a fire dispatch centre. Originated as AS 1670.3-1997. Previous edition 2018. Fourth edition 2024.
Contents:
Section 1: Scope And General
Section 2: Design Criteria
Section 3: Monitored Site Installation
Section 4: Commissioning
Appendix A: (Normative) Network Reliability
Appendix B: (Informative) Wiring Systems — Protection Against Mechanical Damage
Appendix C: (Informative) System Commissioning Statement
Fire Detection, Warning, Control and Intercom Systems.
FP-002
Association of Accredited Certification Bodies; Association of Australasian Acoustical Consultants; Australasian Fire and Emergency Service Authorities Council; Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Industry Group; Australian Institute of Building Surveyors; CSIRO; Deafness Forum of Australia; Engineers Australia; Engineers Australia/ Society of Fire Safety; Fire Protection Association Australia; Hydraulic Consultants Association Australasia; National Electrical and Communications Association; National Fire Industry Association; Property Council of Australia.